Pelco C1487M-D Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Bezpečnostní kamery Pelco C1487M-D. Pelco C1487M-D User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 50
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 • DataFAX (1-559) 292-0435
SD5 Series
Spectra II™ and
Spectra Lite™ Dome
Installation/
Operation Manual
C1487M-D (7/99)
LISTED
U
L
®
®
Zobrazit stránku 0
1 2 3 4 5 6 ... 49 50

Shrnutí obsahu

Strany 1

Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.comIn North America and Canada: Tel (800) 289-9100 or FAX (8

Strany 2 - CONTENTS

10 Pelco Manual C1487M-D (7/99)WIRINGBring wiring to the back box opening in the ceiling. Do not attach the wiring to the back box.You will do that la

Strany 3 - LIST OF TABLES

Pelco Manual C1487M-D (7/99) 11Figure 9. Wiring Diagram for Spectra Lite™CONTROL(RS-422)SPECTRA LITE™ INTERCONNECT BOARDIf you are using a Coaxitron®

Strany 4

12 Pelco Manual C1487M-D (7/99)Table B. 24 VAC Wiring DistancesThe following are the recommended maximum distances for 24 VAC with a 10-percentvoltag

Strany 5 - IN-CEILING MODELS

Pelco Manual C1487M-D (7/99) 13BACK BOX CONNECTIONSRefer to Figure 12 or 13 to attach the wiring to the interconnect circuit board inside the backbox.

Strany 6 - PENDANT MODELS

14 Pelco Manual C1487M-D (7/99)Figure 13. Interconnect Circuit Board Electrical Connections for Spectra Lite™HTR/FANRX–RX+TX–TX+PWR INFUSE1.6 ADOME D

Strany 7 - DESCRIPTION

Pelco Manual C1487M-D (7/99) 15DOME DRIVE1. Turn on power to the back box. The red LED should light to indicate power.If the LED does not light, corre

Strany 8 - HARD CEILING

16 Pelco Manual C1487M-D (7/99)Table D. Switch Settings for SW2 – P-Type ControlNOTES:For Coaxitron® controls, SW2 is not used; set all switches OFF.

Strany 9 - SUSPENDED CEILING

Pelco Manual C1487M-D (7/99) 17Table E. Switch Settings for SW2 – D-Type ControlNOTES:For Coaxitron® controls, SW2 is not used; set all switches OFF.

Strany 10

18 Pelco Manual C1487M-D (7/99)Table E. Switch Settings for SW2 – D-Type Control (continued)Receiver Address Switch SettingSW2-1 SW2-2 SW2-3 SW2-4 SW

Strany 11 - (RS-422)

Pelco Manual C1487M-D (7/99) 19Table E. Switch Settings for SW2 – D-Type Control (continued)Continued on next page117 ON OFF ON OFF ON ON ON OFF118 O

Strany 12 - Back Box Connec

2 Pelco Manual C1487M-D (7/99)CONTENTSSection PageGENERAL ...

Strany 13 - BACK BOX CONNECTIONS

20 Pelco Manual C1487M-D (7/99)Table E. Switch Settings for SW2 - D-Type Control (continued)Continued on next page177 ON OFF OFF OFF ON ON OFF ON178

Strany 14 - Dome Drive

Pelco Manual C1487M-D (7/99) 21Table E. Switch Settings for SW2 - D-Type Control (continued)237 ON OFF ON ON OFF ON ON ON238 OFF ON ON ON OFF ON ON O

Strany 15 - DOME DRIVE

22 Pelco Manual C1487M-D (7/99)INSTALLATION FOR PENDANT MODELSPENDANT-MOUNT INSTALLATION1. Install the pendant dome mount. Refer to the instructions s

Strany 16 - For Coaxitron

Pelco Manual C1487M-D (7/99) 2310. If you are installing an outdoor model, plug the two-pin heater connection in the lowerdome into the mating connect

Strany 17

24 Pelco Manual C1487M-D (7/99)POWER-UP DISPLAYWhen the Spectra II™ dome or Spectra Lite™ dome is powered up or reset, the selectedprotocol, revision

Strany 18

Pelco Manual C1487M-D (7/99) 25ZOOMSPECTRA II™ ZOOMThe Spectra II™ dome can magnify an object up to 128 times. The dome has 16X of opticalzoom and 8X

Strany 19

26 Pelco Manual C1487M-D (7/99)RANDOM, FRAME, AND AUTO SCANNINGProgram preset 97 (30) to start random scanning. Program preset 98 (31) to activate fra

Strany 20

Pelco Manual C1487M-D (7/99) 27In certain situations, the dome will respond as follows:• If a preset has not been set, but an alarm is connected: the

Strany 21 - LOWER DOME

28 Pelco Manual C1487M-D (7/99)PROGRAMMING THE SPECTRA II™ AND SPECTRA LITE™The Spectra II™ and Spectra Lite™ domes can be programmed for the followin

Strany 22 - PENDANT-MOUNT INSTALLATION

Pelco Manual C1487M-D (7/99) 29MAIN MENU ACCESSYou can call up the main menu on your monitor by programming (setting or creating) preset95 (28 if in 3

Strany 23 - OPERATION

Pelco Manual C1487M-D (7/99) 3Section PageLIMIT STOPS ...

Strany 24 - SCAN SPEED

30 Pelco Manual C1487M-D (7/99)3. Press the Iris Open button to enter the Camera submenu.4. Move the joystick up or down to position the cursor beside

Strany 25 - Limit Stops

Pelco Manual C1487M-D (7/99) 31Turning off power to the Spectra II™ and Spectra Lite™ domes does not reset the camera.Camera settings are retained in

Strany 26 - PATTERNS

32 Pelco Manual C1487M-D (7/99)GainThe gain adjusts the signal level of the video output. Increasing the gain in low lightconditions will increase the

Strany 27 - AUXILIARY OUTPUTS

Pelco Manual C1487M-D (7/99) 33PEAK - (Spectra II only) The cursor moves to a numeric value. Increasing this valuewill cause the auto iris circuit to

Strany 28

34 Pelco Manual C1487M-D (7/99)AUTO-FOCUS MODEThere are two auto-focus modes: auto and off.If auto focus is in the auto mode, pressing the Focus Far o

Strany 29 - SENSITIVE

Pelco Manual C1487M-D (7/99) 35AUTO SHARPNESS - (Spectra II only) The cursor moves to one of two choices: Onor Off. Move the joystick up or down to to

Strany 30 - RESET CAMERA

36 Pelco Manual C1487M-D (7/99)To change the line synchronization settings:1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Function

Strany 31 - AGC Mode

Pelco Manual C1487M-D (7/99) 37To select the power-up mode:1. Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) toacc

Strany 32 - AUTO IRIS

38 Pelco Manual C1487M-D (7/99)5. Press the Iris Open button. The cursor will move to the right beside the word On or Off.6. Move the joystick up or d

Strany 33 - SHUTTER SPEED

Pelco Manual C1487M-D (7/99) 39ALARM PATTERN(This section applies to Spectra II™ only.)In response to an alarm, the Spectra II™ dome can do either one

Strany 34 - SHARPNESS

4 Pelco Manual C1487M-D (7/99)GENERALIMPORTANT SAFEGUARDS AND WARNINGSPrior to installation and use of this product, the following WARNINGS should be

Strany 35 - LINE SYNCHRONIZATION

40 Pelco Manual C1487M-D (7/99)AUTO FLIPThere are two auto flip modes: on or off.When the auto flip mode is on, the auto flip feature is enabled. When

Strany 36 - POWER-UP MODE

Pelco Manual C1487M-D (7/99) 41LIMIT STOPSThere are two types of limit stops:Manual limit stopsScan limit stopsWhen manual limit stops are set, a manu

Strany 37 - ALARM RESUME

42 Pelco Manual C1487M-D (7/99)PARK TIME MINUTESThis feature causes the dome to park at preset 1 after a programmed number of minutes ofcontrol inacti

Strany 38 - ALARM PRIORITY

Pelco Manual C1487M-D (7/99) 433. Press the Iris Open button to enter the submenu entitled Other.4. Move the joystick up or down to position the curso

Strany 39 - ZONE BLANK

44 Pelco Manual C1487M-D (7/99)d. Turn on power. If the unit still does not operate, turn off power and replace the domedrive with a unit that is good

Strany 40 - PROPORTIONAL PAN

Pelco Manual C1487M-D (7/99) 45BACK BOX ELECTRONIC ASSEMBLY REMOVALTo remove the back box electronic assembly:1. Turn off power.2. Open the interconne

Strany 41 - Programming Limit Stops

46 Pelco Manual C1487M-D (7/99)SPECIFICATIONSMECHANICALConstructionBack box: AluminumDome drive: Aluminum, ABS plasticLower dome: AcrylicCable EntryIn

Strany 42 - PATTERN LENGTH

Pelco Manual C1487M-D (7/99) 47Ratings: NEMA Type 1–In-ceiling back boxes, all dome drivesNEMA Type 4–Pendant back boxesIP 66–Pendant back boxesWeight

Strany 43 - TROUBLESHOOTING

48 Pelco Manual C1487M-D (7/99)Effective Pixels(NTSC Spectra II™): 768 (H) x 494 (V)(PAL Spectra II™): 752 (H) x 582 (V)(NTSC Spectra Lite™): 510 (H)

Strany 44

Pelco Manual C1487M-D (7/99) 49MONOCHROME (Spectra II™ Only)Signal Format EIA (model DD5AM)CCIR (model DD5AM-X)Scanning System: 2:1 interlaceImage Sen

Strany 45 - MAINTENANCE

Pelco Manual C1487M-D (7/99) 5COMPASS TOOLSAFETYBRACKETCONDUIT FITTING& LOCK NUTT-RAIL CLIPFigure 2. Back Box PartsFigure 1. In-Ceiling Componen

Strany 46 - SPECIFICATIONS

50 Pelco Manual C1487M-D (7/99)REVISION HISTORYManual # Date CommentsC1487M 7/98 Original version.C1487M-A 11/98 Revised the manual to incorporate Spe

Strany 47 - IN-CEILING DOME PENDANT DOME

6 Pelco Manual C1487M-D (7/99)BACKBOXDOMEDRIVELOWERDOMEFigure 3. Pendant ComponentsPENDANT MODELSThe Spectra II™ dome and Spectra Lite™ dome shipping

Strany 48

Pelco Manual C1487M-D (7/99) 7DESCRIPTIONSpectra II™ and Spectra Lite™ domes are capable of the following:• 360° pan rotation • preset positioning• +2

Strany 49

8 Pelco Manual C1487M-D (7/99)SPECTRA LITE™ PENDANT COMPONENTSBB5T-PB Black pendant-mount back box (CE, UL, cUL)BB5T-PG Light gray pendant-mount back

Strany 50 - REGULATORY NOTICES

Pelco Manual C1487M-D (7/99) 9SUSPENDED CEILING1. Remove the ceiling tile from the ceiling. (The ceiling tile cannot be thinner than 0.50inch [1.27 cm

Komentáře k této Příručce

Žádné komentáře