IRD/ERD2000 Series
Receiver
C1506M-A (8/02)
®
INSTALLATION/OPERATION
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - Receiver

IRD/ERD2000 SeriesReceiverC1506M-A (8/02)®INSTALLATION/OPERATION

Strany 2 - 2 C1506M-A (8/02)

10 C1506M-A (8/02)FUSE REPLACEMENTCAUTION: These service instructions are for use by qualified service personnel only. Toreduce the risk of electrica

Strany 3 - CONTENTS

C1506M-A (8/02) 11TROUBLESHOOTINGCheck the wiring connections.If the CX LED does not blink when commands are sent to the receiver, make sure the contr

Strany 4 - CAUTION:

12 C1506M-A (8/02)WIRING TABLESWire GaugeTable A. 24 VAC Wiring Distances TableThe following are the recommended maximum wire distances (transformer

Strany 5 - MOUNTING

C1506M-A (8/02) 13SPECIFICATIONSERD2200ElectricalInput Voltage: 115/230 VAC, 50/60 HzOutput VoltageCamera: 24 VAC (or 115/230 VAC if usingenclosure po

Strany 6 - ERD2200 WIRING

14 C1506M-A (8/02)REGULATORY NOTICESNOTE: This equipment has been tested and found to comply with the limits of a Class B digitaldevice, pursuant to

Strany 7 - Wiring Tables

C1506M-A (8/02) 15REVISION HISTORYManual # Date CommentsC1506M 3/00 Original version.C1506M-A 8/02 Revised manual per ECO #02-8195 to meet UL standard

Strany 8

World Headquarters3500 Pelco WayClovis, California 93612 USAUSA & CanadaTel: 800/289-9100Fax: 800/289-9150InternationalTel: 1-559/292-1981Fax: 1-5

Strany 9 - OPERATION

2 C1506M-A (8/02)

Strany 10 - ERD2200 Wiring

C1506M-A (8/02) 3CONTENTSSection PageIMPORTANT SAFEGUARDS AND WARNINGS ...

Strany 11 - TROUBLESHOOTING

4 C1506M-A (8/02) 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any v

Strany 12 - Total VA consumed

C1506M-A (8/02) 5The IRD/ERD2000 Series Receiver operates Pelco’s fixed speed pan/tilts and domes.The receiver works with standard and extended Coaxit

Strany 13 - C1506M-A (8/02) 13

6 C1506M-A (8/02)ERD2200 WIRINGENCLOSUREPOWER OUTLLNNGROUNDSTUDPOWERTERMINALSMAINPOWER INFigure 2. ERD2200 Receiver Figure 3. ERD2200 Power Connecti

Strany 14 - REGULATORY NOTICES

C1506M-A (8/02) 7ACAC24V 50/60HZ INPUT POWER ~24V ~50/60HZ P/TPOWER SELECT 115/230V ~50/60HZ ACACERD OPTIONTLCOUTVIDEOINPWR CXLENS AUX1 AUX2 C N NOC24

Strany 15 - REVISION HISTORY

8 C1506M-A (8/02)IRD2024 WIRING1. Connect power to the 24 VAC INPUT connector on the rear of the receiver. The receiver’s powerrequirement is a maximu

Strany 16

C1506M-A (8/02) 9When power is applied to the receiver, the green PWR LED on the receiver lights.Whenever the receiver gets a valid Coaxitron control