Shrnutí obsahu

Strany 1 - Camclosure

INSTALLATIONC3425M-E (1/09)IS90 SeriesCamclosure®Indoor Integrated Camera System

Strany 2

10 C3425M-E (1/09)InstallationYou can install the IS90 Series Camclosure integrated camera system as follows:• Mount to the surface of a ceiling/wall

Strany 3 - Contents

C3425M-E (1/09) 11Figure 3. Ceiling/Wall InstallationFigure 4. Concrete Ceiling/Wall InstallationBACK BOXAND SURFACEMOUNT RINGWALL ORCEILING6-32 TOG

Strany 4 - List of Tables

12 C3425M-E (1/09)IN-CEILING INSTALLATION: SUSPENDED CEILING1. Remove the surface mount ring from the back box (refer to Figure 5): a. Place fingers o

Strany 5 - Regulatory Notices

C3425M-E (1/09) 132. Pull the video and power wires to the selected ceiling tile.3. Mount the unit to the ceiling tile (refer to Figure 6 and Figure 7

Strany 6 - Description

14 C3425M-E (1/09)4. Remove an adjacent ceiling tile to access the unit.5. Connect the video cable and wires:• BNC: Connect the BNC connector from the

Strany 7 - PARTS LIST

C3425M-E (1/09) 156. Attach the back box to the mounting surface:• If you have access behind the ceiling/wall (refer to Figure 6 on page 13):(1) Place

Strany 8 - SHOWN ACTUAL SIZE

16 C3425M-E (1/09)5. Attach the surface mount ring and back box to the adapter plate with two 8-32 x 2.50-inch Phillips pan head self-tapping screws (

Strany 9 - Remove the Bubble

C3425M-E (1/09) 17NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of phase with each other and may produce

Strany 10 - Installation

18 C3425M-E (1/09)Camera AdjustmentsTo perform the following camera adjustments, connect a monitor. Then turn on power to the camera and monitor. To u

Strany 11 - C3425M-E (1/09) 11

C3425M-E (1/09) 19To adjust the focus:1. Loosen the focus locking screw.2. Position the inverted dome approximately 0.125 inch (3.175 mm) from the fro

Strany 13 - C3425M-E (1/09) 13

20 C3425M-E (1/09)DN/CH/C SERIES ADJUSTMENTSRefer to Figure 13 to adjust the IS90-DN, IS90-CH, or IS90-C model.Figure 13. Adjusting the IS90-DN/CH/C

Strany 14 - 14 C3425M-E (1/09)

C3425M-E (1/09) 21SW4-4: FlickerlessIn certain lighting conditions, a flicker in the light source may affect camera operation. Flickering can be cause

Strany 15 - C3425M-E (1/09) 15

22 C3425M-E (1/09)3. Each time an adjustment is made, switch back and forth between the camera you are adjusting and the reference camera. Repeat this

Strany 16 - 16 C3425M-E (1/09)

C3425M-E (1/09) 23DAY/NIGHT OPERATIONNOTE: This section only applies to DN model cameras.DN model cameras regularly check the brightness level of the

Strany 17 - C3425M-E (1/09) 17

24 C3425M-E (1/09)DW/CW SERIES (WIDE DYNAMIC RANGE) ADJUSTMENTSRefer to Figure 15 to adjust the IS90-DW or IS90-CW model.Figure 15. Adjusting the IS9

Strany 18 - Camera Adjustments

C3425M-E (1/09) 25SW1-4: Auto White Balance/Manual White BalanceAuto white balance (AWB) is enabled by default (ON).To manually set and lock the white

Strany 19 - 0.125 INCH (3.175 mm)

26 C3425M-E (1/09)SW1-8: Day/Night Operation (DW models only)NOTE: On CW models, SW1-8 is unused and does not affect camera operation.DW model cameras

Strany 20 - DN/CH/C SERIES ADJUSTMENTS

C3425M-E (1/09) 27AUTO IRIS LEVEL ADJUSTMENTThe electronics of the IS90-DW and IS90-CW Series Camclosures automatically adjust the camera to the auto

Strany 21 - Adjusting Vertical Phase

28 C3425M-E (1/09)Camera PositioningRotate and tilt the camera module to position the camera.NOTE: Do not over-rotate the module. Excessively turning

Strany 22 - BLEMISH DETECTION

C3425M-E (1/09) 29Install Liner and Bubble1. To install the liner with a clear bubble (refer to Figure 18):a. Align the studs located on the camera mo

Strany 23 - DAY/NIGHT OPERATION

C3425M-E (1/09) 3ContentsRegulatory Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 24 - SWITCH SETTINGS

30 C3425M-E (1/09)Service ConnectorThe IS90 Series Camclosure integrated camera system includes a service connector that outputs camera video. Use it

Strany 25 - SW1-7: Digital Slow Shutter

C3425M-E (1/09) 31To assemble the cable:1. Attach the CPM 88 miniature coaxial connector to one end of the cable. Follow the directions supplied with

Strany 26 - 26 C3425M-E (1/09)

32 C3425M-E (1/09)SpecificationsGENERALPan/Tilt Adjustment ManualPan 360°Tilt 140° (20° to 160° range) Rotation 360°ConstructionBack Box andSurface Mo

Strany 27

C3425M-E (1/09) 33CAMERA/LENSIf you need technical specifications for the camera itself, refer to the IS90 specification online at www.pelco.com.(Desi

Strany 28 - Camera Positioning

34 C3425M-E (1/09)REVISION HISTORYManual # Date CommentsC3425M 2/07 Original version.C3425M-A 5/07 Updated switch setting and day/night operation desc

Strany 29 - Install Liner and Bubble

PRODUCT WARRANTY AND RETURN INFORMATIONWARRANTYPelco will repair or replace, without charge, any merchandise proved defective in material or workmansh

Strany 30 - Service Connector

Pelco, Inc. Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USAUSA & Canada Tel (800) 289-9100 Fax (800) 289-9150Internatio

Strany 31 - C3425M-E (1/09) 31

4 C3425M-E (1/09)List of Illustrations1 Package Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strany 32 - Specifications

C3425M-E (1/09) 5Regulatory NoticesThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this

Strany 33 - CAMERA/LENS

6 C3425M-E (1/09)DescriptionThe IS90 Series Camclosure® integrated camera system combines a camera and lens package in a small, discreet dome. The sys

Strany 34 - REVISION HISTORY

C3425M-E (1/09) 7Indoor dome, surface/flush mount, smoked and clear bubble, black finishPARTS LISTCamera Type Lens/Iris NTSC PALColor, Wide Dynamic Ra

Strany 35 - WARRANTY

8 C3425M-E (1/09)Figure 1. Package ComponentsIS90 SERIESCAMCLOSURE WITHSMOKED BUBBLELINERADAPTER PLATECLEAR BUBBLESHOWN ACTUAL SIZESHIPPING BOX8-32 X

Strany 36

C3425M-E (1/09) 9Remove the BubbleTurn the bubble counterclockwise and lift (refer to Figure 2). Place the bubble on a nonabrasive surface.If the line